Memosens Analog Converter CYM17

CYM17 enables the use of digital pH sensors and digital oxygen sensors with laboratory fermenters. ©Endress+Hauser

CYM17 enables the use of digital pH sensors and digital oxygen sensors with laboratory fermenters.

With CYM17 you can benefit from all the advantages of Memosens digital sensors. ©Endress+Hauser

With CYM17 you can benefit from all the advantages of digital Memosens sensors, such as insensitivity to moisture, corrosion and dirt.

Converter for Memosens sensors for easy use with laboratory fermenters

The Memosens Analog Converter CYM17 enables the easy use of digital Memosens sensors in your fermentation applications in the laboratory without changing your SOP. Memosens digital technology combines maximum process and data integrity with simple operation. It eliminates any moisture issues and guarantees stable signals after autoclavation.

Ten produkt jest niedostępny na polskim rynku

  • Korzyści

    • Easy exchange of your existing analog sensors. Just install the Memosens sensors to your fermenter and connect them with the converter.

    • Various adapter cables are available for easy connection of one Memosens pH sensor (e.g. CPS171D) and one optical DO...

  • Zastosowanie

    The Memosens Analog Converter CYM17 enables the use of digital Memosens sensors in laboratories in biotechnology industries with your existing fermenter.

Funkcje i specyfikacja

Powrót

Details

  • Zasada pomiaru

    Sensor Oxygen

  • Aplikacja

    CYM17 converter enables easy retrofit of conventional analog pH and oxygen sensor to Memosens CPS171D and COS81D in benchtop fermentation applications.

  • Materiał

    Housing: Aluminum

  • Wymiar

    Height: 36.6 mm (1.44 in)
    Deep: 72 mm (2.8 in)
    Width 140.6 mm (5.5 in)

  • Temperatura procesu

    -5 to 50 °C (20 to 120 °F)

  • Wielkości wejściowe

    M12 socket

  • Wyjście

    Output pH: mV signal according to Nernst equation with 0 mV at pH 7 and -59 mV/pH

    Temperature pH: simulated PT1000

    Output oxygen: 0 to 60 nA with 60 nA at 100% oxygen saturation

    Temperature oxygen: simulated 22 kOhm NTC

  • Zasada pomiaru

    Glass electrode

  • Aplikacja

    CYM17 converter enables easy retrofit of conventional analog pH and oxygen sensor to Memosens CPS171D and COS81D in benchtop fermentation applications.

  • Materiał

    Housing: Aluminum

  • Wymiar

    Height: 36.6 mm (1.44 in)
    Deep: 72 mm (2.8 in)
    Width 140.6 mm (5.5 in)

  • Temperatura procesu

    -5 to 50 °C (20 to 120 °F)

  • Stopień ochrony

    IP54

  • Wielkości wejściowe

    M12 socket

  • Wyjście

    Output pH: mV signal according to Nernst equation with 0 mV at pH 7 and -59 mV/pH

    Temperature pH: simulated PT1000

    Output oxygen: 0 to 60 nA with 60 nA at 100% oxygen saturation

    Temperature oxygen: simulated 22 kOhm NTC

Dokumentacja / Instrukcje obsługi / Oprogramowanie

Akcesoria / Części zamienne

Nr
Order code
Specification