Aby rozpocząć wyszukiwanie, należy wprowadzić minimum 2 znaki.

Digital ORP sensor
Memosens CPS92E

Memosens CPS92E - Digital ORP sensor for chemical processes, paper or pigment production ©Endress+Hauser
Memosens CPS92E - Digital ORP sensor for dispersions, precipitations and emulsions, Ex version ©Endress+Hauser

Memosens converts the measured value to a digital signal and transfers it to the transmitter without a contacting connection. This video shows how Memosens optimizes process control and maintenance.

Memosens 2.0 glass sensor for heavily polluted media in chemical industry, paper, pigment production

Memosens CPS92E with platinum cap is specialized on media with a high content of suspended solids such as dispersions, precipitations or emulsions. The open aperture prevents fouling and ensures the most reliable measurement. Thanks to Memosens 2.0 digital technology, CPS92E combines maximum process integrity with simple operation. It resists moisture, enables lab calibration and offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.

  • Produkty podstawowe

  • Łatwe w doborze, montażu i obsłudze

Poziom zaawansowania

Prostota obsługi

  • Produkty standardowe

  • Niezawodne, wytrzymałe i łatwe w utrzymaniu

Poziom zaawansowania

Prostota obsługi

  • Produkty zaawansowane

  • Wysoka funkcjonalność i wygoda użytkowania

Poziom zaawansowania

Prostota obsługi

  • Produkty specjalistyczne

  • Zaprojektowane z myślą o wymagających procesach

Poziom zaawansowania

Prostota obsługi

Zależna od urządzenia

Segmentacja FLEX Poziom zaawansowania Prostota obsługi
  • F
  • L
  • E
  • X

Segment Fundamental

Zaspokoi Twoje podstawowe potrzeby pomiarowe

Poziom zaawansowania
Prostota obsługi
  • F
  • L
  • E
  • X

Segment Lean

Z łatwością obsłuży Twoje codzienne procesy

Poziom zaawansowania
Prostota obsługi
  • F
  • L
  • E
  • X

Segment Extended

Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom

Poziom zaawansowania
Prostota obsługi
  • F
  • L
  • E
  • X

Segment Xpert

Sprosta Twoim najbardziej wymagającym pomiarom

Poziom zaawansowania
Prostota obsługi

Zależna od urządzenia

Ten produkt jest niedostępny na polskim rynku

  • Kluczowe parametry

    • Zakres pomiarowy

      –1 500 to 1 500 mV

    • Temperatura procesu

      0 to 110 °C (32 to 230 °F)

    • Ciśnienie procesu

      0.8 to 14 bar (11.6 to 203 psi) (absolute)

please wait Loading alternative products

Szybki wybór

Wybierz jedną z zaproponowanych przez nas opcji
Cenansprzedaży
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

lub

Indywidualna konfiguracja

Kontynuuj wybór z uwzględnieniem wszystkich możliwych opcji
  • Korzyści

    • Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.

    • Open aperture for application in heavily soiled media...

  • Zastosowanie

    • Chemical processes

    • Pulp and paper industry

    • Contaminated media and suspended solids
      - Dispersions
      - Precipitations
      - Emulsions

    With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.

Funkcje i specyfikacja

Powrót

Details

  • Zasada pomiaru

    Sensor ORP / Redox

  • Aplikacja

    • Chemical processes

    • Pulp and paper industry

    • Contaminated media:

    • Solids

    • Emulsions

    • Precipitation reactions

    • Dispersions

  • Montaż

    Montaż

  • Charakterystyka

    Digital ORP electrodes with open aperture for contaminated media and integrated temperature sensor

  • Zakres pomiarowy

    –1 500 to 1 500 mV

  • Zasada działania

    Gel compact electrode with open aperture and measuring part as platinum cap

  • Konstrukcja

    All shaft lengths with temperature sensor
    Advanced gel technology

  • Materiał

    Sensor shaft: Glass to suit process

    ORP measuring element: Platinum

    Metal lead: Ag/AgCl

    O-ring: FKM

    Process coupling: PPS fiber-glass reinforced

    Nameplate: Ceramic metal oxide

  • Wymiar

    Diameter: 12 mm (0.47 inch)
    Shaft lengths: 120, 225 and 360 mm
    (4.72, 8.86 and 14.17 inch)

  • Temperatura procesu

    0 to 110 °C (32 to 230 °F)

  • Ciśnienie procesu

    0.8 to 14 bar (11.6 to 203 psi) (absolute)

  • czujnik temperatury

    NTC 30k

  • Dopuszczenia Ex

    With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
    hazardous areas Zone 0, Zone 1 and Zone 2.

  • Podłączenie

    Inductive, contactless connection head with Memosens 2.0 technology

  • Stopień ochrony

    IP68

Dokumentacja / Instrukcje obsługi / Oprogramowanie

Akcesoria / Części zamienne

Nr
Order code
Specification
    • Order code 71038228

      Memoclip label Memosens sensor

      for assignment of sensors to measuring loop. 100 sensor clips with printable labels

    • Order code CPY20-

      Technical buffer solution CPY20

      pH quality buffer solution, referenced to primary reference material of PTB and standard reference material of NIST. in DAkkS accredited buffer Laboratory.

    • Order code CPY4-

      KCL-Electrolyte solution CPY4

      For liquid filled electrodes