Multicap T DC21TEN
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Dokumentacja / Instrukcje obsługi / Oprogramowanie
-
Multicap T DC 12 TE, Multicap T DC 11/16/21/26 TEN, Multicap T DC 11/16/21/26 TESTechnical Information
Compact capacitive level probes (with European certificates).
Fully and partially insulated rod and rope probes.Karta katalogowa (TI) -
Multicap T DC 12 TE DC 11/16/21/26 TEN DC 11/16/21/26 TESOperating Instructions
Compact capacitive level probes (with European certificates). Fully and partially insulated rod and rope probes.
Instrukcja obsługi (BA) -
Probes and electronic inserts
Approval No.: KEMA 99 ATEX 3122
ATEX II 2 G
ATEX 2(2) G
Protection:
EEx ia IIC T3...T6
EEx d[ia] IICT3...T6Instrukcje dot. bezpieczeństwa Ex (XA) -
Safety Instructions
Probes and electronic inserts
II 1/2 G, II 2 G EEx ia IIC/IIB T6
PTB 98 ATEX 2215 X (ATEX)Instrukcje dot. bezpieczeństwa Ex (XA) -
Safety Instructions
Probes and electronic inserts
II 1/2 G, II 2 G EEx ia IIC T6, EEx ia IIB T6
PBT 98 ATEX 2215 X (ATEX)Instrukcje dot. bezpieczeństwa Ex (XA) -
Probes and electronic inserts
Approval No.: EG 04 005-a
ATEX II 3 G
Protection:
EEx nA/nC II T6Instrukcje dot. bezpieczeństwa Ex (XA) -
Brewery application: CIP unit, Application 5
Meas. point 4: level switch CIP-tank
Application 1: LiquiphantRozwiązania branżowe (SO)Angielski -
Dairy application: CIP unit, Application 4
Meas. point 3: level measurement CIP-tank
Application 2: multicapRozwiązania branżowe (SO)Angielski -
Juice application: CIP unit, Application 4
Meas. point 3: level measurement CIP-tank
Application 2: multicapRozwiązania branżowe (SO)Angielski -
Brewery application: Brewhouse, Application 3
Meas. point 2: level measurement mash and wort vessel
Application 2: capacitiveRozwiązania branżowe (SO)Angielski -
Brewery application: CIP unit, Application 4
Meas. point 3: level measurement CIP-tank Application 2: multicap
Rozwiązania branżowe (SO)Angielski -
Brewery application: CIP unit, Application 6
Meas. point 4: level switch CIP-tank
Application 2: ultrasonicRozwiązania branżowe (SO)Angielski -
Brewery application: CIP unit, Application 7
Meas. point 5: temperature measurement CIP-unit
Rozwiązania branżowe (SO)Angielski -
GSD Single, GSD_EH_PA_LE_Multicap_0x153A_V01_00_PALIB, 14.04.2014 (Level,
Multicap, 0x153A)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_Multicap_153A_0x03_0x01, 07.01.2019 (Level, Multicap, 0x153A)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Multicap_FEC14_V1_0, 21.10.2020 (Level, Multicap, 0x153A)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Multicap_FEC12_V1_0___1_2, 23.10.2020 (Level, Multicap, 0x0008)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral
Akcesoria / Części zamienne
-
-
Order code
Phase out spares
-
Order code
Phase out repairs
-
Order code
12/2010
-
Order code 014850-0007
O-ring 73,0 x 3,0 MVQ 50
-
Order code 52008495
-
Order code 918709-0020
Cover F3/T3 (M94) Alu, coated
Material: Aluminium, coated. Ex e / non Ex.
-
Order code 942174-0010
-
Order code 942175-0000
-
Order code 015238-0000
O-ring 88,0 x 3,0 NBR 70 +PTFE
-
Order code 014850-0000
O-ring 73,0 x 3,0 EPDM 60 +PTFE
Usage: housing cover F6/F10, terminal compartment cover T3.
-
Order code 52014048
Sealing ring DIN7603-A 33x39 FA, 5pcs.
Process gasket. Usage: Process connections G1.
-
-
Następca
-
Produkty podstawowe
- Łatwe w doborze, montażu i obsłudze
Poziom zaawansowania
Prostota obsługi
-
Produkty standardowe
- Niezawodne, wytrzymałe i łatwe w utrzymaniu
Poziom zaawansowania
Prostota obsługi
-
Produkty zaawansowane
- Wysoka funkcjonalność i wygoda użytkowania
Poziom zaawansowania
Prostota obsługi
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
Segmentacja FLEX Poziom zaawansowania Prostota obsługi - F
- L
- E
- X
Segment Fundamental
Zaspokoi Twoje podstawowe potrzeby pomiarowe
Poziom zaawansowania Prostota obsługi - F
- L
- E
- X
Segment Lean
Z łatwością obsłuży Twoje codzienne procesy
Poziom zaawansowania Prostota obsługi - F
- L
- E
- X
Segment Extended
Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom
Poziom zaawansowania Prostota obsługi - F
- L
- E
- X
Segment Xpert
Sprosta Twoim najbardziej wymagającym pomiarom
Poziom zaawansowania Prostota obsługi Zależna od urządzenia
-