Probfit CPA465

Product picture of: Probfit CPA465

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Funkcje i specyfikacja

Powrót

Details

  • Zasada pomiaru

    Sensor Oxygen

  • Aplikacja

    Food, pharmaceuticals, process

  • Montaż

    Retractable holder

  • Charakterystyka

    Open and closed tank (min. DN80)

  • Konstrukcja

    manual or pneumatic, can be fully automated with CPC30 / 310.- Integrated rinse chamber (Z-shape) with

  • Materiał

    Holder : stainless steel 1.4435 (AISI316L)Sealing : different materials available

  • Wymiar

    Immersion deepth : 47 - 120mm
    (1.83inch - 4.68inch)

  • Temperatura procesu

    max. 140°C
    (284°F)

  • Ciśnienie procesu

    max. 10bar
    (145psi)

  • Podłączenie

    DN25 thread adapter nut, Triclamp, Varivent, APV, dairy fitting DN50, flange DN50/PN10, flange ASME 2" 150 lbs.

  • Dodatkowe dopuszczenia

    - 3.1.B EN 10204- EHEDG / 3A

  • Zasada pomiaru

    Glass electrode

  • Aplikacja

    Food, pharmaceuticals, process

  • Montaż

    Retractable assembly

  • Charakterystyka

    Open and closed tank (min. DN80)

  • Konstrukcja

    - manual or pneumatic, can be fully automated with CPC30 / 310 - integrated rinse chamber (Z-shape) with connection G1/4" and G1/2".

  • Materiał

    Assembly: stainless steel 1.4435 (AISI316L)Sealing: different materials available

  • Wymiar

    Immersion depth: 47 - 120 mm
    (1.83 inch - 4.68 inch)

  • Temperatura procesu

    max. 140°C
    (284°F)

  • Ciśnienie procesu

    max. 10 bar
    (145 psi)

  • Podłączenie

    DN25 thread adapter nut, Triclamp, Varivent, APV, dairy fitting DN50, flange DN50/PN10, flange ASME 2" 150 lbs.

  • Dodatkowe dopuszczenia

    - 3.1.B EN 10204 - EHEDG / 3A

  • Zasada pomiaru

    Sensor ORP / Redox

  • Aplikacja

    Food, pharmaceuticals, process

  • Montaż

    Retractable holder

  • Charakterystyka

    Open and closed tank (min. DN80)

  • Konstrukcja

    - manual or pneumatic, can be fully automated with CPC30 / 300.- Integrated rinse chamber (Z-shape) with connection G1/4" and G1/2".

  • Materiał

    Holder : stainless steel 1.4435 (AISI316L)Sealing : different materials available

  • Wymiar

    Immersion deepth : 47 - 120mm

  • Temperatura procesu

    max. 140°C

  • Ciśnienie procesu

    max. 10bar

  • Podłączenie

    DN25 thread adapter nut, Triclamp, Varivent, APV, dairy fitting DN50, flange DN50/PN10, flange ASME 2" 150 lbs.

  • Dodatkowe dopuszczenia

    - 3.1.B EN 10204- EHEDG / 3A

Dokumentacja / Instrukcje obsługi / Oprogramowanie

Akcesoria / Części zamienne

Nr
Order code
Specification
  • Następca