Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Produkty zaawansowane
Poziom zaawansowania
Prostota obsługi
Produkty podstawowe
Poziom zaawansowania
Prostota obsługi
Produkty standardowe
Poziom zaawansowania
Prostota obsługi
Produkty zaawansowane
Poziom zaawansowania
Prostota obsługi
Produkty specjalistyczne
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
| Segmentacja FLEX | Poziom zaawansowania | Prostota obsługi |
|---|---|---|
Segment Fundamental Zaspokoi Twoje podstawowe potrzeby pomiarowe |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Lean Z łatwością obsłuży Twoje codzienne procesy |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Extended Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Xpert Sprosta Twoim najbardziej wymagającym pomiarom |
Poziom zaawansowania
|
Prostota obsługi
Zależna od urządzenia |
System design and specifications for the multi optic calibration
and verification kit
| EN | PL | ||
|
26/06/2023
|
|
|
|
Język: |
Angielski |
|
Wersja: |
26/06/2023 |
|
Rozmiar pliku: |
478.7 KB |
|
Nazwa pliku: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
| EN | PL | ||
|
09/07/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Język: |
Angielski |
|
Wersja: |
09/07/2026 |
|
Rozmiar pliku: |
504.3 KB |
|
Nazwa pliku: |
TI01635CEN_0426.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | PL | ||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Język: |
Angielski |
|
Wersja: |
08/09/2025 |
|
Rozmiar pliku: |
949 KB |
|
Nazwa pliku: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details for Rxn-10
probe optics: Raman immersion optics (KIO1), non-contact
optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic
(KRBMO), bio sleeve (KRBSL), and Raman optic system for
single use (KRSU1)
| EN | PL | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Język: |
Angielski |
|
Wersja: |
08/06/2026 |
|
Rozmiar pliku: |
2.9 MB |
|
Nazwa pliku: |
BA02171CEN_0426.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | PL | ||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Język: |
Angielski |
|
Wersja: |
08/09/2025 |
|
Rozmiar pliku: |
1.8 MB |
|
Nazwa pliku: |
BA02160CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
| EN | PL | ||
|
26/06/2023
|
|
|
|
Język: |
Angielski |
|
Wersja: |
26/06/2023 |
|
Rozmiar pliku: |
996.4 KB |
|
Nazwa pliku: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
| EN | PL | ||
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Język: |
Angielski |
|
Wersja: |
02/12/2024 |
|
Rozmiar pliku: |
1.6 MB |
|
Nazwa pliku: |
KA01546CEN_0424.pdf |
Quick start guide for Rxn-10 probe optics: Raman immersion optics
(KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio
multi optics (KRBMO), bio sleeves (KRBSL), and
Raman optic system for single use (KRSU1)
| EN | PL | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Język: |
Angielski |
|
Wersja: |
08/06/2026 |
|
Rozmiar pliku: |
1.1 MB |
|
Nazwa pliku: |
KA01551CEN_0426.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Język: |
Japoński |
|
Wersja: |
04/10/2024 |
|
Rozmiar pliku: |
2.5 MB |
|
Nazwa pliku: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Język: |
Angielski |
|
Wersja: |
26/06/2025 |
|
Rozmiar pliku: |
363.4 KB |
|
Nazwa pliku: |
PU01611CEN_0125.pdf |