Kluczowe parametry
-
Measuring range
More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously
2 measuring ranges per component
Automatic measuring range switching (adjaustable)
2 limit values per component
Measuring ranges depend on application and combination of measuring components
Zastosowanie
The MCS300P is an extractive process photometer for measuring gaseous or liquid media. It measures IR- and VIS-active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring toxic or flammable mixtures, it features special process cells with integrated protective devices, such as double seals and purge gas chambers on both sides.
Process monitoring in production of vinyl chloride or isocyanate
Process control in the chemical industry
Process monitoring in the production of plastics
Monitoring of exhaust gas purification plants
Device properties:
Simultaneous measurement of up to 6 components
Process cells up to 60 bar and 200 °C available
Automated sample point switching
Protective devices for measurement of toxic or flammable mixtures
Extended operation via PC and SOPAS ET software
Flexible I/O module system
Korzyści
Automatic adjustment without expensive test gases
Integration into existing networks
Integration of external parameters like temperature or pressure
Suitable for explosive environments
Easy installation and maintenance thanks to transparent, compact design
Segment Xpert
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
-
Produkty podstawowe
- Łatwe w doborze, montażu i obsłudze
Poziom zaawansowania
Prostota obsługi
-
Produkty standardowe
- Niezawodne, wytrzymałe i łatwe w utrzymaniu
Poziom zaawansowania
Prostota obsługi
-
Produkty zaawansowane
- Wysoka funkcjonalność i wygoda użytkowania
Poziom zaawansowania
Prostota obsługi
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
| Segmentacja FLEX | Poziom zaawansowania | Prostota obsługi |
|---|---|---|
Segment Fundamental Zaspokoi Twoje podstawowe potrzeby pomiarowe |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Lean Z łatwością obsłuży Twoje codzienne procesy |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Extended Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Xpert Sprosta Twoim najbardziej wymagającym pomiarom |
Poziom zaawansowania
|
Prostota obsługi
Zależna od urządzenia |
-
-
Karta katalogowa (TI)
Opto Box
The Opto-Box is part of the modular MODIOS I/O system and
is installed in an existing I/O module box system.EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
979.6 KB
Nazwa pliku:
8031175_AE00_TI_OptoBox_en_V2-2_2012-08_EHS.pdf
-
-
-
Karta katalogowa (TI)
I/O Module Box
available for MCS300P or MCS300P Ex
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
947.3 KB
Nazwa pliku:
8031177_AE00_TI_IO-Modulebox_en_V1-1_2012-08_EHS.pdf
-
-
-
Karta katalogowa (TI)
MCS300P Technical Information
Multicomponent Analyzer System
(This document is only valid in combination with the
"Operating Instructions MCS300P" or
"Operating Instructions MCS300P-Ex".)EN PL 01/08/2025Język:
Angielski
Wersja:
01/08/2025
Rozmiar pliku:
1.5 MB
Nazwa pliku:
8031256_AE00_TI_MCS300P_en_V1-2_2025-08_EHS.pdf
-
-
-
Karta katalogowa (TI)
HCX8 Heat Control
The HC8X is an 8-channel heat control. It serves to regulate single
and multi-phase heating circuits.EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
1.5 MB
Nazwa pliku:
8031183_AE00_TI_HC8X_en_V1-1_2013-01_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
SFU
Gas Sampling Unit
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.6 MB
Nazwa pliku:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
SFU weatherproof enclosure
Gas Sampling Unit with Weatherproof Enclosure
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.6 MB
Nazwa pliku:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
MCS300P Ex
Multi-Component Analysis System
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
4.3 MB
Nazwa pliku:
8029886_AE00_OI_MCS300P_Ex_en_V1-9_2025-03_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
FGK - High-Pressure Gas and Liquid Cell
The FGK cell is part of a measuring system suitable for
analyzing gases and liquids.EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
1.8 MB
Nazwa pliku:
8030448_AE00_OI_FGK_en_V3-0_2012-07_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
AGK Gas Cell
The cell is part of a measuring system for analyzing gas mixtures and
is used exclusively for the spectrometric analysis of gases under
process conditions.EN PL 01/09/2025Język:
Angielski
Wersja:
01/09/2025
Rozmiar pliku:
1.5 MB
Nazwa pliku:
8030439_AE00_OI_AGK_en_V2-0_2025-09_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
PGK
Gas Cell
EN PL 01/04/2025Język:
Angielski
Wersja:
01/04/2025
Rozmiar pliku:
959 KB
Nazwa pliku:
8030445_AE00_OI_PGK_en_V2-2_2025-04_EHS.pdf
-