iTHERM TT412
Imperial Hygienic Thermowell,
US Style

iTHERM TT412 Imperial Hygienic Thermowell ©Endress+Hauser

iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck

iTHERM TT412 Imperial Hygienic Thermowell ©Endress+Hauser

iTHERM TT412 Imperial Hygienic Thermowell with Tri-Clamp process connection

iTHERM TT412 Imperial Hygienic Thermowell ©Endress+Hauser

iTHERM TT412 Imperial Hygienic Thermowell with QuickNeck and weld-in adapter

State of the art Tee and Elbow elements with best-in-class hygienic design ©Endress+Hauser

Designed for hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.

Ten produkt jest niedostępny na polskim rynku

  • Korzyści

    • iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used

    • All common hygienic process connections

    • International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability

    • Fast response time owing to reduced tips with thin walls

    • State of the art Tee and Elbow elements, without...

  • Zastosowanie

    Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries

    • Pressure range up to 40 bar (580 psi)

    • For increased protection requirements of the temperature sensor regarding physical and chemical...

Funkcje i specyfikacja

Powrót

Details

  • Zasada pomiaru

    Fabricated Thermowell

  • Charakterystyka / Aplikacja

    imperial style

    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)

    hygienic process connections

    QuickNeck for easy and cost saving recalibration

  • Head connection

    QuickNeck

    NPT1/2

  • Maksymalna długość zanurzeniowa

    48" (1.219 mm)

  • Przyłącze technologiczne

    weld in adaptor

    clamp connections acc. to ISO2852

    thread acc. to ISO 228 for liquiphant adaptor APV Inline
    Varivent

    T- and corner pieces DIN11865

  • Średnica rdzenia osłony

    1/4" (6,35 mm)

    3/8" (9,525 mm)

    1/2" (12,7mm)

  • Medium contact material

    316L

  • Gładkość części wchodzących w kontakt z medium (Ra)

    < 30 μinch (0,76 μm)

    < 15 µinch(0,38 μm)

    < 15 μinch (0,38 µm) electropolished

  • Kształt końcówki

    straight

    reduced

  • Zakres temperatur

    -200...650 °C (-328...1.202 °F)

  • Maks. ciśnienie procesu (statyczne)

    40 bar (580 psi)

  • Maks. ciśnienie procesu w temp. 400 °C

    depends on process connection

Dokumentacja / Instrukcje obsługi / Oprogramowanie

Akcesoria / Części zamienne

Nr
Order code
Specification